Industry: Healthcare

Thermal Insulating Coating for Hospital Canopy – Condensation Control

Industry: Healthcare / New Construction | Service: Specialty Coatings / Thermal Insulation | Contractor: TMI Coatings, LLC (AMPP QP 1 & QP 2 Certified)

Challenge

A hospital undergoing new construction needed a condensation control solution for its building canopy. Uncontrolled condensation on metal decking in healthcare environments creates a moisture-drip risk, promotes mold growth, and can compromise both structural integrity and indoor air quality, particularly problematic in facilities subject to healthcare building codes and infection control standards. The project’s general contractor needed a specialty subcontractor who could mobilize quickly, apply a thick-film thermal insulating coating to specification, and complete the work without disrupting the broader construction schedule.

Solution

TMI Coatings, LLC (TMI) mobilized a crew to the site within ten days of contract award and executed the full scope on an accelerated timeline. TMI’s superintendent conducted a pre-work walkthrough with the GC to coordinate safety protocols, schedule integration, and performance expectations.

TMI’s crew poly-covered all adjacent surfaces and equipment to protect finished work in the active construction zone. Surfaces were cleaned with compressed air and solvent to remove contaminants and ensure proper adhesion. TMI applied a waterborne rust-inhibiting primer to the galvanized decking, followed by Tnemec Aerolon Acrylic Series 971, a thick-film thermal insulating coating, at an average 100 mils DFT, meeting the engineered thickness specification required to prevent condensation formation on the canopy’s metal substrate. Aerolon 971 creates a thermal barrier that keeps surface temperatures above the dew point, eliminating condensation without the need for traditional mechanical insulation.

Result

TMI completed the installation safely and on the compressed schedule, with minimal disruption to the hospital’s overall construction timeline. The canopy now carries a seamless thermal insulating barrier engineered to prevent condensation, moisture drip, and associated mold risk for the life of the building. The project demonstrated TMI’s ability to mobilize rapidly, integrate into active construction environments managed by general contractors, and apply specialty coating systems beyond the capabilities of standard painting subcontractors.

Why TMI Coatings

TMI Coatings is an AMPP QP 1 and QP 2 certified industrial coatings contractor with 40 years of experience across healthcare, institutional, manufacturing, and infrastructure environments. TMI’s specialty coatings capability includes thermal insulating systems, condensation-control coatings, fireproofing, and high-performance protective coatings that require precise film build control and product-specific application expertise. TMI hires, trains, and deploys its own field crews nationwide, with NACE CIP Level 3 certified inspection personnel for in-house quality assurance.

FAA-Compliant Helipad Coating Restoration at Level 1 Trauma Center

Industry: Healthcare / Level 1 Trauma Center | Service: Specialty Coatings / Helipad Restoration | Contractor: TMI Coatings, LLC (AMPP QP 1 & QP 2 Certified)

Challenge

The University of Colorado Hospital, a Level 1 Trauma Center, commissioned TMI Coatings to restore its rooftop helipad. After 10 years of service, the original coating system had worn down, creating safety hazards for flight crews and hospital staff moving gurneys across the surface. The helipad’s design pattern and identification lettering also required complete reinstallation to FAA compliance standards. The critical constraint was operational continuity: the hospital had to schedule the helipad closure well in advance and arrange alternative emergency transport protocols for the duration of the project. There was no room for schedule overrun on a trauma center helipad.

Solution

TMI Coatings, LLC (TMI) coordinated the project timeline with the hospital’s operations team to minimize the helipad’s time out of service. After the owner cleared all movable equipment, TMI mechanically abraded all surfaces to remove loose and delaminating coating and establish a profile for coating adhesion.

TMI applied a primer rated for metal substrates and compatible with the helipad’s glycol heating coil system, an important compatibility requirement as the coils prevent ice accumulation on the landing surface during winter operations. TMI incorporated an anti-slip aggregate into the coating system to enable safe personnel movement across the surface, including gurney transport between the aircraft and the building. TMI then installed the helipad’s FAA-compliant design pattern, identification markings, and lettering using high-contrast colors optimized for low-visibility approach conditions.

Result

TMI restored the helipad to full operational status on schedule, returning this critical life-safety asset to service within the hospital’s planned closure window. The Manager of Safety and Environment of Care stated TMI was easy to work with, communicated well, and restored the 10-year-old helipad on a Level 1 Trauma Center to its original condition. The helipad now provides FAA-compliant visibility markings, anti-slip personnel safety, and a durable coating system compatible with the structure’s glycol heating infrastructure.

Why TMI Coatings

TMI Coatings is an AMPP QP 1 and QP 2 certified industrial coatings contractor with 40 years of experience in healthcare, institutional, and critical infrastructure environments. Helipad restoration requires a contractor who understands FAA marking standards, anti-slip performance requirements, substrate compatibility with embedded heating systems, and the schedule discipline required when a life-safety asset is taken out of service. TMI deploys its own field crews nationwide with NACE CIP Level 3 certified inspection personnel.